The NuWall® wall panel can be used for either new or retrofit construction. This concealed fastened system creates a clean, uninterrupted wall on a building. The NuWall® system is based on a 12-inch module. This means that when using NuWall® over existing metal panels, the existing panel ribs must be 6 inches or 12 inches on center.

Gauge
  • 24 gauge (standard)
  • 22 gauge (optional)
Length
  • Max= 40′-0″, contact Garco for longer panels.
Dimensions
  • 12″ wide X 2 ½” high
Finish
Usage
  • For retrofit construction, a 2″ thick layer of Blanket Insullation may be added between existing panel and the NuWall® panels.

drawing_nuwall

12″ NuWall® 22 Gauge – Negative Design Loads

22 GAUGE
SPAN TYPE 2.50 3.00 3.50 4.00 5.00 5.50 5.50 6.00 6.50 7.00
1592 LOAD 228.80 211.00 192.00 174.00 157.00 140.40 125.00 110.00 97.00 83.20
DESIGN LOAD 114.40 105.50 96.00 87.00 78.50 70.20 62.50 55.00 48.50 41.60

 
 

12″ NuWall® 24 Gauge – Negative Design Loads

24 GAUGE
SPAN TYPE 2.50 3.00 3.50 4.00 5.00 5.50 5.50 6.00 6.50 7.00
1592 LOAD 169.52 157.00 145.00 134.00 122.00 110.24 98.00 86.00 74.00 62.40
DESIGN LOAD 84.76 78.50 72.50 67.00 61.00 55.12 49.00 43.00 37.00 31.20

 
 

12″ NuWall® 26 Gauge – Negative Design Loads

24 GAUGE
SPAN TYPE 2.50 3.00 3.50 4.00 5.00 5.50 5.50 6.00 6.50 7.00
1592 LOAD 176.80 157.00 136.00 117.00 98.00 83.20 72.00 66.00 62.00 57.20
DESIGN LOAD 88.40 78.50 68.00 58.50 49.00 41.60 36.00 33.00 31.00 28.60

 
 

12″ NuWall® 24 Gauge – Positive Design Loads

24 GAUGE
SPAN TYPE 2.50 3.00 3.50 4.00 5.00 5.50 5.50 6.00 6.50 7.00
1592 LOAD 234.00 225.00 216.00 207.00 198.00 187.20 173.00 158.00 141.00 124.80
DESIGN LOAD 117.00 112.50 108.00 103.50 99.00 93.60 86.50 79.00 70.50 62.40

 
 

12″ NuWall® 26 Gauge – Positive Design Loads

24 GAUGE
SPAN TYPE 2.50 3.00 3.50 4.00 5.00 5.50 5.50 6.00 6.50 7.00
1592 LOAD 166.40 154.00 142.00 131.00 119.00 109.20 101.00 94.00 89.00 83.20
DESIGN LOAD 83.20 77.00 71.00 65.50 59.50 54.60 50.50 47.00 44.50 41.60

 
 

Notes:
  1. The above loads were derived from uplift tests done in accordance with ASTM E-1592.
  2. All values are interpolated and/or extrapolated from tests performed at spans of 2′-6″, 5′-0″ and 7′-0″.
  3. Test results are highlighted.
  4. Design Load contains a 2.00 factor of safety.
  5. *** indicates insufficient data.
  6. These values do not consider fastener pullout or pullover, fastener attachment must be designed separately.
  7. This material is subject to change without notice. Please contact Garco for most current data.

Allowable Uniform Loads In Pounds Per Square Foot – 16″ Panels
drawing_battenlok

24 Gauge (Fy = 50 Ksi)
SPAN
TYPE
LOAD
TYPE
SPAN IN FEET
2.5 3.0 3.5 4.0 4.5 5.0 5.5
SINGlE LIVE 162.0 135.0 115.7 101.3 90.0 74.0 61.1
2-SPAN LIVE 162.0 128.1 94.1 72.1 56.9 46.1 38.1
3-SPAN LIVE 162.0 135.0 115.7 90.1 71.2 57.6 47.6
4-SPAN LIVE 162.0 135.0 109.8 84.1 66.5 53.8 44.5
22 Gauge (Fy = 50 Ksi )
SPAN
TYPE
LOAD
TYPE
SPAN IN FEET
2.5 3.0 3.5 4.0 4.5 5.0 5.5
SINGlE LIVE 233.4 194.5 166.7 145.9 123.0 99.7 82.4
2-SPAN LIVE 233.4 184.6 135.6 103.8 82.1 66.5 54.9
3-SPAN LIVE 233.4 194.5 166.7 129.8 102.6 83.1 68.7
4-SPAN LIVE 233.4 194.5 158.3 121.2 95.8 77.6 64.1

Note: For 12″ panel information please contact Star.

Allowable Uniform Loads Notes:
  1. Allowable loads are based on uniform span lengths and Fy = 50 ksi.
  2. LIVE LOAD is limited by bending, shear, combined shear and bending and web crippling.
  3. Allowable loads consider a maximum deflection ratio of L/180.
  4. The weight of the panel has not been deducted from the allowable loads.
  5. THE ALLOWABLE UNIFORM LOADS ARE NOT FOR USE WHEN DESIGNING PANELS TO RESIST WIND UPLIFT.
  6. Please contact manufacturer or manufacturer’s website for most current allowable wind uplift loads.
  7. The use of any field seaming machine other than that provided by the manufacturer may damage the panels, void all warranties and will void all engineering data.

The engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recommended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If fur ther information or guidance regarding cold-formed design practices is desired, please contact the manufacturer.

EFFECTIVE NOVEMBER 3, 2004 SUBJECT TO CHANGE WITHOUT NOTICE