  • Description
  • Advantages & Attributes
  • Allowable Uplift Pressure

Metl-Span’s CFR Retro-Seam™ insulated metal standing seam roof panel featuring Roof Hugger’s® sub-purlin system combines the technical innovation and product reliability for which we’re known and more critically, provides a long-term, cost effective and energy efficient solution to your roofing challenge.Retro-Seam is a light-gauge structural member, notched to span over the original roof’s ribs or corrugation, which is positioned directly over the building’s framing system. The member is attached to the roof purlins through the bottom flange of the structural member and the existing roof sheet. The new insulated metal standing seam roof is then attached to the new member.

Click here to view Color Chart

Metl-Span’s CFR Retro-Seam insulated metal standing seam roof panel with the innovative Roof Hugger sub-purlin system is the smart solution economically because it:

  1. Maximizes thermal performance which translates into measurably lower energy and usage costs;
  2. Eliminates the need and associated cost of removing the existing roof;
  3. Improves the integrity of original design loadings and meets International Building Code (IBC) requirements;
  4. Provides unsurpassed weathertight performance—your building’s integrity is preserved for decades;
  5. Saves an unparalleled 50-70% on labor costs.
Metl-Span 2″ CFR 30 Roof Panel

Maximum Allowable Uplift Pressure (PSF)
Span 16Ga. Purlins 14Ga. Purlins
1.50 163.30 176.40
2.00 122.40 132.30
2.50 97.90 105.80
3.00 81.00 88.20
3.50 69.90 75.60
4.00 61.00 66.10
4.50 54.00 58.80
5.00 48.50 51.60

 

Metl-Span 2″ CFR 36 Roof Panel

Maximum Allowable Uplift Pressure (PSF)
Span 16Ga. Purlins 14Ga. Purlins
1.50 135.00 160.30
2.00 102.00 120.30
2.50 81.00 96.20
3.00 68.00 80.20
3.50 58.00 68.70
4.00 51.00 60.10
4.50 45.00 53.40
5.00 39.90 46.70

 

Metl-Span 2″ CFR 42 Roof Panel

Maximum Allowable Uplift Pressure (PSF)
Span 16Ga. Purlins 14Ga. Purlins
1.50 115.00 136.30
2.00 87.00 102.20
2.50 69.00 81.80
3.00 58.00 68.10
3.50 49.90 58.40
4.00 43.00 51.10
4.50 38.80 45.40
5.00 34.90 39.70

 

Notes:

  1. All panels have a 26ga interior steel skin and a 24ga exterior skin.
  2. All roof panel clips tabs are fabricated from 20ga steel.
  3. All roof panel clip bases are fabricated from 12ga steel.
  4. All interior suport clips are attached to 16ga purlins with (3ea) 1/4-14×3″ #3SD.
  5. All interior support clips are attached to 14ga purlins with (2ea) 1/4-14×3″ #3SD.
  6. All 14ga purlin uplift values are baed on ASTM E1592 uplift testing & NOA 05-0830.04 Evaluation Report.
  7. All 16ga purlin uplift values are based on empirical data derived from Dade Cty NOA 05-0830.04.
  8. All 16ga purlin uplift values are based on a pullout safety factor of 3.0 per AISI 2001.
  9. All 16ga purlin uplift values are based on a clip prying coefficient of 1.6 applied to the interior uplift reaction.
  10. All uplift values are based on a minimum of a 3-span or 4-span condition.
  11. All uplift values are based on a maximum deflection of L/240.
CFR-42 ROOF SYSTEM ALLOWABLE UNIFORM LOAD CHART
CFR PANEL
THICKNESS
DESIGN
CRITERIA
ALLOWABLE LOAD (PSF)
PANEL SPAN (FT)
2.5 3.0 4.0 5.0 6.0 7.0
42″ WIDE, 2″ THICK
2 FASTENERS/CLIP
BENDING & SHEAR 143.8 118.0 86.2 67.7 55.7 47.3
DEFLECTION (L/240) 120.3 98.3 70.6 53.8 42.4 34.3
CONNECTION 58.5 53.5 46.8 42.5 34.5 28.5
42″ WIDE, 2.5″ THICK
2 FASTENERS/CLIP
BENDING & SHEAR 165.5 135.8 99.3 77.9 64.0 54.3
DEFLECTION (L/240) 147.5 121.0 87.6 67.4 53.7 43.9
CONNECTION 65.0 58.5 50.3 45.1 36.6 30.4
42″ WIDE, 3″ THICK
2 FASTENERS/CLIP
BENDING & SHEAR 184.9 152.0 111.2 87.2 71.5 60.6
DEFLECTION (L/240) 171.5 141.1 102.8 79.6 63.9 52.7
CONNECTION 71.3 63.5 53.6 47.6 38.7 32.2
42″ WIDE, 4″ THICK
2 FASTENERS/CLIP
BENDING & SHEAR 196.2 161.6 118.6 93.0 76.2 64.5
DEFLECTION (L/240) 210.0 173.4 127.3 99.4 80.6 67.2
CONNECTION 84.0 73.4 59.9 51.8 42.4 35.7
42″ WIDE, 5″ THICK
3 FASTENERS/CLIP
BENDING & SHEAR 223.1 184.2 135.6 106.5 87.3 73.8
DEFLECTION (L/240) 235.4 194.9 143.8 112.9 92.2 77.3
CONNECTION 86.5 75.5 61.8 53.4 44.4 37.9
42″ WIDE, 6″ THICK
3 FASTENERS/CLIP
BENDING & SHEAR 247.2 204.5 151.0 118.9 97.6 82.5
DEFLECTION (L/240) 247.8 205.4 152.2 120.1 98.5 82.9
CONNECTION 88.8 77.6 63.5 55.0 46.3 40.0

 

  1. Based on CFR-42 panel with 24 ga. exterior face (min Fy = 50 ksi) and 26 ga. interior face (min Fy = 33 ksi).
  2. Based on attachment at interior supports with CFR panel clip and (2 or 3 as shown above) 1/4″-14 Self-Drilling
    Tek 3 screws in min. 14 gage steel or (2) 1/4″-14 Self-Drilling Tek 3 screws in min. 12 gage steel. Two fasteners per clip are required at end supports.  In lieu of self-drilling screws, self-tapping screws may be used.
  3. Allowable positive load is the lowest value of panel bending strength, shear strength & deflection limit.
  4. Allowable suction load is the lowest value of panel bending strength, shear strength, deflection limit and connection strength for each fastener pattern.
  5. Connection loads may be increased with Fab-Lok.  Consult Garco Buildings for additional loads.
  6. The loads based on panel stress and deflection design criteria are derived from ASTM E-72 structural testing.
    The allowable loads are calculated with a factor of safety of 2.5 and 3.0 for bending and shear stresses, respectively, and deflection limitation of L/240 and with a factor of safety of 2.0 for connection strength.
  7. The clip fastener capacity was determined from manufacturer fastener pullout data and the allowable loads are calculated with a factor of safety of 3.0.
  8. The structural capacity of the purlins are not considered and must be examined independently.
  9. Multiple spans are based on 3 or more spans conditions.
  10. For allowable snow loads please consult factory.